Router |
Attribute |
Commands |
Index |
Value Range |
Crosspoint |
RTRMUTEXP |
SET, GET, SETD, GETD |
1 & 2 |
1 = unmuted 0 = muted |
Note: For attributes with 2 Index fields, Index1 is the input/row, and Index2 is the output/column.
Example: Set Device 1 Router Crosspoint at Instance 98 Row 4 Column 5 to muted.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
RTRMUTEXP |
98 |
4 |
5 |
0 |
<LF> |
Result: SET 1 RTRMUTEXP 98 4 5 0 <LF>
Source Selection |
Attribute |
Commands |
Index |
Value Range |
Source |
SRCSELSRC |
SET, GET, SETD, GETD |
2 |
0 = no source/muted 1 = source 1 2 = source 2 3 = source 3 |
Level |
SRCSELLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-100 ~ 12 * |
* Can contain a decimal number.
Example:Set Device 1 Source Selection Source at Instance ID 99 Source 2 selected.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
SRCSELSRC |
99 |
None |
1 |
2 |
<LF> |
Result: SET 1 SRCSELSRC 99 1 2 <LF>
Example: Set Device 1 Source Selection Volume at Instance ID 99 to -54dB for source input 3.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
SRCSELLVL |
99 |
3 |
None |
-54 |
<LF> |
Result:SET 1 SRCSELLVL 99 3 -54 <LF>