Meter Blocks

 

Meters

Attribute

Commands

Index

Value Range

Signal

SPMTRSTATE

GET, GETD

1

0 = no signal

1 = signal

Peak

PKMTRLVL

GET, GETL, GETD

1

-100 ~ 36 *

RMS

RMSMTRLVL

GET, GETL, GETD

1

-100 ~ 36 *

Logic

LGCMTRSTATE

GET, GETD

1

0 = no signal

1 = signal

* Can contain a decimal number.

 

Note: Meters only use GET and GETL commands, which do not include a Value. Instead, Audia will respond to these GET/GETL commands with the requested value (current level).

 

Example: Get Device 1 RMS Meter Level at Instance 48 Meter 1.

 

Command

Device_#

Attribute

Instance_ID

Index_1

Index_2

Value

Line_Feed

GET

1

RMSMTRLVL

48

1

None

None

<LF>

 

Result: GET 1 RMSMTRLVL 48 1 <LF> (use GET/GETL commands only)