Analog Inputs |
Attribute |
Commands |
Index |
Value Range |
Input Gain |
MICGAIN |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
0, 6, 12, 18, 24, 30, 36, 42, 48, 54, 60, 66 |
Input Level |
INPLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-100 ~ 12 * |
Phantom Power |
PHPWR |
SET, GET, SETD, GETD |
1 |
0 = off 1 = on |
Input Mute |
INPMUTE |
SET, GET, SETD GETD |
1 |
0 = unmuted 1 = muted |
Invert Polarity |
INPINVRT |
SET, GET, SETD, GETD |
1 |
0 = normal 1 = inverted |
* Can contain a decimal number.
Example: Set Device 1 Input Level at Instance ID 6 Input 3 to -10dB.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
INPLVL |
6 |
3 |
None |
-10 |
<LF> |
Result: SET 1 INPLVL 6 3 -10 <LF>
AEC Inputs |
Attribute |
Commands |
Index |
Value Range |
Input Gain |
AECMICGAIN |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
0, 6, 12, 18, 24, 30, 36, 42, 48, 54, 60, 66 |
Input Level |
AECINPLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-100 ~ 12 * |
Phantom Power |
AECPHPWR |
SET, GET, SETD, GETD |
1 |
0 = off 1 = on |
Input Mute |
AECINPMUTE |
SET, GET, SETD, GETD |
1 |
0 = unmuted 1 = muted |
Invert Polarity |
AECNPINVRT |
SET, GET, SETD, GETD |
1 |
0 = normal 1 = inverted |
Enable AEC |
AECENABLE |
SET, GET, SETD, GETD |
1 |
0 = off 1 = on |
NLP Strength |
AECNLP |
SET, GET, SETD, GETD |
1 |
0 = off 1 = soft 2 = medium 3 = aggressive |
Noise Reduction |
AECNR |
SET, SETL, SETD, GETD, GET, GETL |
1 |
0, and 6 ~ 15 |
* Can contain a decimal number.
Example: Set Device 1 AEC NLP Strength at Instance ID 24 Input 3 to aggressive.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
AECNLP |
24 |
3 |
None |
3 |
<LF> |
Result: SET 1 AECNLP 24 3 3 <LF>
Analog Outputs |
Attribute |
Commands |
Index |
Value Range |
Output Level |
OUTLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
2 |
-100 ~ 12 * |
Output Mute |
OUTMUTE |
SET, GET, SETD, GETD |
2 |
0 = unmuted 1 = muted |
Output Full Scale Level ** |
OUTFS |
SET, SETL, SETD, GETD, GET, GETL |
2 |
-31, 0, 6, 12, 18, 24 |
Invert Polarity |
OUTINVRT |
SET, GET, SETD, GETD |
2 |
0 = normal 1 = inverted |
Mic Level Pad *** |
OUTPAD |
SET, GET, SETD, GETD |
2 |
0 = off 1 = on |
* Can contain a decimal number.
** Supported only on FLEX OP-2e cards (-31 & 24 values supported on SOLO 4x12 outputs 1~4).
*** Supported on all FLEX output cards (and SOLO 4x12 outputs 1~4).
Example: Set Device 2 Output Mute at Instance ID 3 Output 4 to muted.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
2 |
OUTMUTE |
3 |
None |
4 |
1 |
<LF> |
Result: SET 2 OUTMUTE 3 4 1 <LF>
Power Amp |
Attribute |
Commands |
Index |
Value Range |
Mute |
AMPMUTE |
SET, GET, SETD, GETD |
2 |
0 = unmuted 1 = muted |
Invert Polarity |
AMPINVRT |
SET, GET, SETD, GETD |
1 |
0 = normal 1 = inverted |
Gain |
AMPGAIN |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
2 |
0 ~ 24 |
Clip Limiter |
AMPCLIPLIM |
SET, GET, SETD, GETD |
2 |
0 = disabled 1 = enabled |
Impedance |
AMPIMPED |
SET, GET, SETD, GETD |
2 |
1 = 4 ohm 2 = 6 ohm 3 = 8 ohm 4 = auto |
AudiaFUSION |
Attribute |
Commands |
Index |
Value Range |
FUSION Output Mute |
FUSAMPMUTE |
SET, GET, SETD, GETD |
2 |
0 = unmuted 1 = muted |
FUSION aMP iNVERT |
FUSAMPINVRT |
SET, GET, SETD, GETD |
2 |
0 = off 1 = on |
FUSION Clip/Limiter |
FUSAMPCLIPLIM |
SET, GET, SETD, GETD |
2 |
0 = disabled 1 = enabled |
FUSION Amp Imped |
FUSAMPIMPED |
SET, GET, SETD, GETD |
2 |
1 = 4 Ohm 2 = 6 Ohm 3 = 8 Ohm 4 = autodetect |
Networked Paging Station-1 |
Attribute |
Commands |
Index |
Value Range |
Level |
NPSLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
-100 ~ 12* |
Mute |
NPSMUTE |
SET, GET, SETD, GETD |
None |
0 = unmuted 1 = muted |
* Can contain a decimal number.
TI-2 Dialer |
Attribute |
Commands |
Index |
Value Range |
Caller ID |
TICID |
GET, GETD |
None |
None |
Full User Caller ID |
TICIDUSER |
GET, GETD |
None |
None |
Hook-Flash |
TILINE |
FLASH |
None |
None |
Hook-Switch State |
TIHOOKSTATE |
SET, GET, SETD, GETD |
None |
0 = off-hook 1 = on-hook |
Speed Dial Tel. Number |
TISDENTRY |
SET, GET, SETD, GETD |
1 |
enter the phone number |
Speed Dial Name |
TISDLABEL |
SET, GET, SETD, GETD |
1 |
enter the name |
Last Number Dialed |
TILASTNUM |
GET, GETD |
None |
None |
Speed Dial Entry to Dial |
TISPEEDDIAL |
DIAL |
None |
1 ~ 16 |
Phone Number to Dial |
TIPHONENUM |
DIAL |
None |
enter the phone number |
Redial |
TILASTDIALED |
DIAL |
None |
None |
Note: The TI-2 can insert delay while dialing a phone number by inserting commas where desired (each comma provides 1 second of delay). Most PBX systems require delay after acquiring an outside line. Also, multiple TIPHONENUM commands can be used to dial the individual digits of a phone number.
Example: Get Device 1 TI-2 Caller ID Informatioin at Instance ID 23.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
GET |
1 |
TICID |
23 |
None |
None |
None |
<LF> |
Result:GET 1 TICID 23 <LF>
Note: GET 1 TICID 23 will return: "" if there is no caller ID information available. If there is CID information available, it will return in the format "MMDDHHmmXXXXXXXXXX" where the "X's" represent the ten digit phone number. For example: "040211235035551212".
Example: Get Device 1 TI-2 Full User Caller ID Information at Instance ID 23.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
GET |
1 |
TICIDUSER |
23 |
None |
None |
None |
<LF> |
Result: GET 1 TICIDUSER 23 <LF>
Note: GET 1 TICIDUSER 23 will return: "" if there is no caller ID information available. The first set of quotes contains the date and time in the format MMDDHHmm. The second set of quotes represents the incoming phone number in the format 5036417287. The third set of quotes contains the name of the caller. If there are quotes contained within the name, there will be a backslash preceding the quotes withing the name, i.e. David \"Dawg\" Grisman".
Example: Set Device 1 TI-2 Speed Dial Entry at Instance ID 23 Speed Dial 16 to 1-800-826-1457.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
TISDENTRY |
23 |
16 |
None |
18008261457 |
<LF> |
Result: SET 1 TISDENTRY 23 16 18008261457 <LF> (dashes in phone number are optional)
Example: Dial Device 1 TI-2 Phone Number To Dial at Instance ID 23 of 1-800-826-1457.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
DIAL |
1 |
TIPHONENUM |
23 |
None |
None |
18008261457 |
<LF> |
Result: DIAL 1 TIPHONENUM 23 18008261457 <LF> (use DIAL instead of SET/GET commands)
TI-2 Receive |
Attribute |
Commands |
Index |
Value Range |
Receive Level |
TIRXLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
-100 ~ 12 * |
Receive Mute |
TIRXMUTE |
SET, GET, SETD, GETD |
None |
0 = unmuted 1 = muted |
Number of Rings Before Auto-Answer |
TIAUTOANSWER |
SET, GET, SETD, GETD |
None |
0 = off 1, 2, 3, 4, or 5 |
Line Echo Cancellation |
TIRXLEC |
SET, GET, SETD, GETD |
None |
0 = off 1 = on |
Noise Suppression |
TIRXNS |
SET, GET, SETD, GETD |
None |
0 = off 1 = on |
* Can contain a decimal number.
TI-2 Transmit |
Attribute |
Commands |
Index |
Value Range |
Transmit Level |
TTXLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
None |
-100 ~ 0 * |
Transmit Mute |
TITXMUTE |
SET, GET, SETD, GETD |
None |
0 = unmuted 1 = muted |
* Can contain a decimal number.
Example: Mute the TI-2 Transmit Block at Instance ID 21.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
TITXMUTE |
21 |
None |
None |
1 |
<LF> |
CobraNet Input |
Attribute |
Commands |
Index |
Value Range |
CobraNet RX Bundle |
CNINBNDL |
SET, GET, SETD, GETD |
None |
1-65279 |
CobraNet Input Level |
CNINLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-100 ~ 12 * |
CobraNet Input Mute |
CNINLVL |
SET, GET, SETD, GETD |
1 |
0 = unmuted 1 = muted |
CobraNet Input Invert |
CNININVRT |
SET, GET, SETD, GETD |
1 |
0 = off 1 = on |
* Can contain a decimal number.
CobraNet Output |
Attribute |
Commands |
Index |
Value Range |
CobraNet TX Bundle |
CNOUTBNDL |
SET, GET, SETD, GETD |
None |
1-65279 |
CobraNet Output Level |
CNOUTLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
2 |
-100 ~ 0 * |
CobraNet Output Mute |
CNOUTLVL |
SET, GET, SETD, GETD |
2 |
0 = unmuted 1 = muted |
CobraNet Output Invert |
CNOUTINVRT |
SET, GET, SETD, GETD |
2 |
0 = off 1 = on |
* Can contain a decimal number.
EXPI |
Attribute |
Commands |
Index |
Value Range |
EXPI RX Bundle |
EXPIBNDL |
SET, GET, SETD, GETD |
None |
1-65279 |
EXPI Input Level |
EXPILVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-100 ~ 12 * |
EXPI Input Mute |
EXPILVL |
SET, GET, SETD, GETD |
1 |
0 = unmuted 1 = muted |
EXPI Input Invert |
EXPIINVRT |
SET, GET, SETD, GETD |
1 |
0 = off 1 = on |
* Can contain a decimal number.
EXPO |
Attribute |
Commands |
Index |
Value Range |
EXPO TX Bundle |
EXPOBNDL |
SET, GET, SETD, GETD |
None |
1-65279 |
EXPO Output Level |
EXPOLVL |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
2 |
-100 ~ 0 * |
EXPO Output Mute |
EXPOLVL |
SET, GET, SETD, GETD |
2 |
0 = unmuted 1 = muted |
EXPO Output Invert |
EXPOINVRT |
SET, GET, SETD, GETD |
2 |
0 = off 1 = on |
* Can contain a decimal number.