Equalizer Blocks
Graphic EQ |
Attribute |
Commands |
Index |
Value Range |
EQ Band Level |
GEQLVLBND |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-30 ~ 15 * |
Bypass All Bands |
GEQBYPALL |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
Note: Index1 represents the filter to be controlled. Graphic EQ filters are numbered from left to right, and the selected band is displayed in the upper left hand corner of the Graphic EQ dialog screen in Audia software. Use this number as Index1 for Graphic EQ strings.
Example: Set Device 2 Graphic EQ Bypass All Bands at Instance 9 to bypass.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
2 |
GEQBYPALL |
9 |
None |
None |
1 |
<LF> |
Result: SET 2 GEQBYPALL 9 1 <LF>
Parametric EQ |
Attribute |
Commands |
Index |
Value Range |
EQ Bandwidth |
PEQBWBND |
SET, SETL, GET, GETL, SETD, GETD |
1 |
0.010 ~ 4.000 * |
Bypass EQ Band |
PEQBYPBND |
SET, GET, SETD, GETD |
1 |
0 = active 1 = bypassed |
Center Freq. |
PEQFCBND |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
20 ~ 20000 |
EQ Band Level |
PEQLVLBND |
SET, SETL, GET, GETL, INC, DEC, SETD, GETD |
1 |
-30 ~ 15 * |
Bypass All Bands |
PEQBYPALL |
SET, GET, SETD, GETD |
None |
0 = active 1 = bypassed |
* Can contain a decimal number.
Note: Index1 represents the filter to be controlled. Parametric EQ filters are initially numbered from left to right, and the selected band is displayed in the upper left hand corner of the Parametric EQ dialog screen in Audia software. Use this number as Index1 for Parametric EQ strings.
Example: Increment Device 1 Parametric EQ Band Level at Instance 11 Band 2 by 2dB.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
INC |
1 |
PEQLVLBND |
11 |
2 |
None |
2 |
<LF> |
Result: INC 1 PEQLVLBND 11 2 2 <LF>
Feedback Suppressor |
Attribute |
Commands |
Index |
Value Range |
Reset All Filters |
FBSRESET |
SET |
None |
None |
Fix All Filters |
FBSFIXALL |
SET, GET, SETD, GETD |
None |
0 = not fixed 1 = fix all |
Example: Set Device 1 Feedback Suppressor Reset All Filters at Instance 4.
Command |
Device_# |
Attribute |
Instance_ID |
Index_1 |
Index_2 |
Value |
Line_Feed |
SET |
1 |
FBSRESET |
4 |
None |
None |
None |
<LF> |
Result: SET 1 FBSRESET 4 <LF>